Keep away from flammable and explosive materials: Running generators should be kept away from flammable and explosive materials to prevent safety hazards .

Ensure sufficient cooling water: Before starting the generator, it is necessary to ensure sufficient cooling water If there is no cooling water in the water tank or if cooling water is added after starting, .

Good ventilation: The generator set should be installed in a well ventilated and clean computer room The computer room should be equipped with exhaust facilities,.

After waiting for the LCD screen to start, place the "manual automatic " switch in the "automatic (electric) " position Press the "AUTO " button on the controller to enter the self starting standby mode of the unit .

Clean the surface of the radiator: Regularly use compressed air or clean water to clean accumulated dust, dirt, and oil stains from the outlet side to the inlet side of the radiator .

Use fuel saving and smoke reducing device: Fix the fuel saving and smoke reducing device vertically in the front oil circuit of the fuel injection pump and connect it to a DC power supply .

Corrosion and rusting: When the generator set is idle for a long time, it may be affected by corrosion and rusting This is mainly due to the moisture and salt in the air .

Insufficient battery power: Insufficient battery power can cause the generator to fail to start It is necessary to check the battery voltage and charge or replace the battery if necessary .

Long term idling operation: When a diesel engine is idling for a long time, due to the low temperature inside the cylinder and insufficient fuel combustion, .

Avoid frequent engine start stop: In winter, frequent engine start stop can cause water vapor condensation, increasing the risk of water vapor accumulation and freezing .

Preparation: Ensure that the vehicle has cooled down and use a jack to lift and secure the vehicle onto the safety bracket Disassemble necessary components such as drive shaft, clutch cover, etc to access the flywheel .

The main reasons for the tripping of Cummins generator sets include internal and external faults of the generator, misoperation of protective devices, and misoperation by duty personnel .

Accurate fuel supply calibration: Follow the data in the user manual to accurately check and adjust the fuel supply advance angle After running for 500 hours, recalibration is required to maintain efficient operation .

The main reasons why diesel generators are difficult to start can be summarized as follows: fuel system problems, electrical system problems, compression system problems, and environmental factors .

The control system of Weifang generators mainly consists of controllers, sensors, actuators, and protective devices .